Low Temperature Sterilizer

Product Overview

Low temperature sterilizers are designed for medical devices and instruments that may be damaged by conventional high-temperature steam sterilization. They support sterilization processes for heat-sensitive materials and equipment used in hospitals, central sterile supply departments (CSSDs), and medical device processing facilities.

The product range includes hydrogen peroxide plasma sterilizers, 100% ethylene oxide (EO) sterilizers, and mixed EO gas sterilizers. Each technology uses a different sterilization medium and process, allowing buyers to select equipment according to instrument materials, device structures, processing capacity, and sterilization requirements.

 
 

Low Temperature Sterilizer Types

Hydrogen Peroxide Plasma Sterilizer

Hydrogen peroxide plasma sterilizers use hydrogen peroxide as the sterilizing agent. The process combines vacuum, hydrogen peroxide injection, sterilization, plasma treatment, and ventilation.

This technology is suitable for selected heat-sensitive medical instruments, including rigid endoscopes, optical instruments, catheters, surgical instruments, and diagnostic devices. Instrument compatibility should be confirmed according to material composition, lumen dimensions, packaging requirements, and the sterilizer model.

Available models include PS60, PS100, PS120, and PS200, with chamber volumes from 60 L to 200 L.

100% Ethylene Oxide Sterilizer

The 100% EO sterilizer uses ethylene oxide gas to process medical devices that require low-temperature sterilization. EO gas can penetrate porous packaging materials and reach device surfaces and internal structures when the packaging and load configuration are suitable.

Typical applications include endoscopes, anesthesia equipment, dialysis equipment, ventilators, catheters, tracheal tubes, surgical instruments, and selected rubber or plastic products.

Available models include EOGS-70, EOGS-120, EOGS-200, EOGS-300, and EOGS-500, with chamber capacities from 70 L to 500 L.

Mixed Ethylene Oxide Sterilizer

Mixed EO sterilizers use a gas mixture of 80% ethylene oxide and 20% carbon dioxide. They are designed for larger-scale sterilization applications involving medical devices and selected heat-sensitive products.

The equipment range covers chamber volumes from 2.0 m³ to 30 m³. The process includes heating, temperature holding, pre-vacuum, leak testing, humidification, EO injection, sterilization, and ventilation.

This series is suitable for facilities that require larger chamber capacities and a defined EO sterilization workflow. The required chamber volume, utilities, installation conditions, and process parameters should be confirmed according to the intended load and facility layout.

Model Selection and Technical Specifications

Hydrogen Peroxide Plasma Sterilizer Specifications

Model Chamber Volume Power Supply Rated Power External Dimensions (W × D × H)
PS60 60 L 220 V / 50 Hz 2.2 kVA 770 × 660 × 1400 mm
PS100 100 L 380 V / 50 Hz 2.8 kVA 760 × 790 × 1600 mm
PS120 120 L 380 V / 50 Hz 3.2 kVA 860 × 790 × 1600 mm
PS200 200 L 380 V / 50 Hz 4.6 kVA 1110 × 770 × 1760 mm

The plasma sterilizer provides Rapid, Standard, and Enhanced cycle options. The hydrogen peroxide concentration is 56%–63%. The system uses microcomputer control and an automatic operating process.

The main process stages include:

  • Vacuum
  • Hydrogen peroxide injection
  • Sterilization
  • Vacuum
  • Plasma treatment
  • Ventilation

Cassette Type and Bottle Type configurations are available. With the Bottle Type configuration, hydrogen peroxide can be replenished locally after the supplied bottle has been used, subject to the required consumable specification. A double-door configuration is optional.

100% EO Sterilizer Specifications

Model Chamber Capacity Power Supply Rated Power Temperature Relative Humidity External Dimensions (W × D × H)
EOGS-70 70 L 220 V / 50 Hz 1.7 kVA 50–55°C 70% 770 × 660 × 1400 mm
EOGS-120 120 L 220 V / 50 Hz 2.3 kVA 50–55°C 70% 760 × 790 × 1600 mm
EOGS-200 200 L 220 V / 50 Hz 4.1 kVA 50–55°C 70% 1110 × 770 × 1760 mm
EOGS-300 300 L 220 V / 50 Hz 4.1 kVA 50–55°C 70% 1140 × 780 × 1760 mm
EOGS-500 500 L 220 V / 50 Hz 4.1 kVA 50–55°C 70% 1140 × 880 × 1870 mm

The 100% EO sterilizer uses ethylene oxide gas as the sterilizing medium. Its listed operating features include digital operation, process monitoring, alarm functions, and digital record printing. Equipment selection should take into account the load type, packaging, sterilization process, ventilation requirements, and the facility's EO handling arrangements.

Mixed EO Sterilizer Specifications

Model Chamber Volume Rated Power
EOGS2.0 2.0 m³ 6 kW
EOGS2.5 2.5 m³ 7 kW
EOGS3.0 3.0 m³ 7 kW
EOGS3.5 3.5 m³ 8 kW
EOGS4.0 4.0 m³ 8 kW
EOGS5.0 5.0 m³ 10 kW
EOGS5.5 5.5 m³ 11 kW
EOGS6.0 6.0 m³ 12 kW
EOGS6.5 6.5 m³ 12 kW
EOGS7.0 7.0 m³ 12 kW
EOGS8.0 8.0 m³ 13 kW
EOGS9.0 9.0 m³ 14 kW
EOGS10 10 m³ 20 kW
EOGS12 12 m³ 22 kW
EOGS15 15 m³ 28 kW
EOGS20 20 m³ 35 kW
EOGS26 26 m³ 36 kW
EOGS30 30 m³ 40 kW

The mixed EO sterilizer uses an 80% EO and 20% CO₂ gas mixture. For the EOGS2.0 model, the listed sterilization time is 3–99 hours. Process parameters and installation requirements for other models should be confirmed against the selected equipment configuration and intended load.

Instrument Compatibility and Application Considerations

Selecting a low temperature sterilizer requires more than matching chamber volume. Buyers should check the instrument's material, structure, packaging, and processing requirements before confirming a model.

For hydrogen peroxide plasma sterilization, applicable instrument materials include selected aluminum, copper, glass, stainless steel, titanium, polycarbonate, polyurethane, PVC, PE, PEEK, PTFE, polypropylene, and PMMA components.

The plasma process is not suitable for absorbent materials, liquids, creams, oils, powders, insufficiently dry items, single-ended closed-lumen devices, implants, or devices that cannot withstand vacuum pressure.

Lumen dimensions are also important. For the PS120 model, the stated limitations include stainless steel lumens with an internal diameter below 1 mm and a length above 500 mm, and PTFE lumens with an internal diameter below 1 mm and a length above 2,000 mm.

For the PS200 model, the stated limitations include stainless steel lumens with an internal diameter below 0.8 mm and a length above 300 mm, and PTFE lumens with an internal diameter below 1 mm and a length above 1,000 mm.

For EO sterilization, buyers should evaluate the device material, packaging permeability, load arrangement, gas exposure requirements, and post-sterilization ventilation or aeration needs. Compatibility and process suitability should be confirmed for the specific device and load before ordering.

Configuration and Supply Options

Equipment configuration should match the sterilization method and the facility's operating requirements.

  • Sterilization method: Hydrogen peroxide plasma, 100% EO, or mixed EO gas.
  • Chamber capacity: Selection from compact chamber models to larger-volume systems.
  • Hydrogen peroxide supply: Cassette Type or Bottle Type configuration for plasma sterilizers.
  • Door configuration: Double-door configuration is available as an option for the plasma sterilizer.
  • Process requirements: Cycle selection and process configuration according to the sterilization method and intended load.
  • Installation planning: Equipment dimensions, power supply, room layout, and site conditions should be reviewed before order confirmation.

For project-based orders, buyers can provide the intended instruments, estimated load volume, required sterilization method, and facility information to confirm the suitable model and configuration.

Manufacturing, Quality and Technical Support

The product range covers hydrogen peroxide plasma sterilizers and ethylene oxide sterilizers for medical and healthcare applications.

Available project support includes equipment design adjustments, capacity adjustments, and special-function customization. Technical documentation can include equipment drawings, installation blueprints, and factory layout drawings. Technical personnel can provide on-site guidance and installation support according to project requirements.

The company also lists OEM/ODM services, after-sales support, and spare-parts availability. ISO 9001, ISO 14001, ISO 13485, and CE-related information is listed at company level. Buyers should confirm the applicable certificates, declarations, and regulatory documentation for the specific model and destination market before purchase.

Information to Include in Your Inquiry

To help identify a suitable low temperature sterilizer, please provide:

  • Sterilization method: Hydrogen peroxide plasma, 100% EO, or mixed EO.
  • Instrument or product type: Such as endoscopes, catheters, surgical instruments, or other heat-sensitive devices.
  • Material and structure: Including material composition and lumen dimensions where applicable.
  • Required chamber capacity: Estimated load volume or processing quantity per batch.
  • Packaging requirements: Packaging material and loading arrangement.
  • Facility conditions: Available power supply, installation space, and relevant site requirements.
  • Destination market: Country or region where the equipment will be installed.

Our team can review the application details and provide model and configuration information for your project.

Frequently Asked Questions

1. What is the difference between a hydrogen peroxide plasma sterilizer and an EO sterilizer?

A hydrogen peroxide plasma sterilizer uses hydrogen peroxide and a plasma treatment stage. An EO sterilizer uses ethylene oxide gas as the sterilizing medium. The appropriate method depends on the instrument material, structure, packaging, and validated processing requirements.

2. Which chamber capacity should I choose?

The required capacity depends on the quantity and size of instruments processed per batch, the loading arrangement, and the expected daily workload. Buyers should provide their typical load details before selecting a model.

3. Can a plasma sterilizer process instruments with narrow lumens?

Lumen compatibility depends on the sterilizer model, lumen material, internal diameter, and length. The PS120 and PS200 models have specified lumen limitations. Please provide the instrument's lumen dimensions for compatibility review.

4. What is the difference between Cassette Type and Bottle Type plasma sterilizers?

The two configurations differ in hydrogen peroxide supply. The Bottle Type configuration allows local replenishment of hydrogen peroxide after the supplied bottle has been used, provided the replacement consumable meets the required specification.

5. Are 100% EO sterilizers and mixed EO sterilizers the same?

No. The 100% EO series uses 100% ethylene oxide gas, while the mixed EO series uses a gas mixture of 80% ethylene oxide and 20% carbon dioxide. They have different equipment capacities and process configurations.

6. What information is required before equipment installation?

The installation plan should consider equipment dimensions, power supply, room layout, site utilities, ventilation, and the requirements associated with the selected sterilization method. For EO equipment, the facility's gas handling and ventilation arrangements should also be reviewed before installation.

7. Can the equipment be customized for a specific project?

Equipment design, chamber capacity, and selected functions can be discussed according to project requirements. Buyers should provide the intended application, load information, facility conditions, and required configuration for technical evaluation.

As one of the most professional low temperature sterilizer manufacturers and suppliers in China, we're featured by quality products and good service. Please rest assured to buy customized low temperature sterilizer at competitive price from our factory. Also, quotation is available. Ethylene Oxide Sterilizer, h2o2 sterilizer, Hydrogen Peroxide sterilizer

whatsapp

Phone

E-mail

Inquiry