Washer Disinfector
Medical Washer Disinfector for CSSD – Model Selection, Cleaning Capacity & Configurations
The medical washer disinfector is designed for automated cleaning, thermal disinfection and drying of reusable medical instruments in CSSD and other medical facilities. Three models are available: Clean180, Clean320 and Clean520, with chamber capacities of 180 L, 320 L and 520 L respectively. Buyers can compare tray capacity, door configuration, equipment dimensions and utility requirements to select a washer disinfector for their CSSD or medical equipment project.
1. Cleaning Capacity & Instrument Compatibility
The CSSD washer disinfector is suitable for processing a range of reusable medical instruments and containers, including:
- General surgical instruments
- Rigid endoscopes
- Respiratory and anesthesia tubes
- Dental handpieces
- Medical instrument containers
- Glass containers (optional application)
Different instrument types require suitable loading arrangements. Available washer disinfector cleaning racks include:
- Drying trough cleaning rack
- Four-layer instrument cleaning rack
- Bowl and dish cleaning rack
- Anesthesia and respiratory tube cleaning rack
Select the rack configuration according to the instruments, containers and loading requirements of your facility. For specialized instruments, confirm the required rack arrangement and connection details before ordering.
2. Washer Disinfector Models & Specifications
The Clean180, Clean320 and Clean520 washer disinfector models offer different chamber capacities and loading configurations.
| Specification | Clean180 | Clean320 | Clean520 |
|---|---|---|---|
| Chamber capacity | 180 L | 320 L | 520 L |
| Standard tray quantity | 4 | 8 | 15 |
| Tray dimensions | 480 × 250 × 70 mm | 480 × 250 × 70 mm | 480 × 250 × 70 mm |
| Door configuration | Manual door | Manual door | Automatic door |
| Pass-through design | Not specified | Not specified | Double-door |
| External dimensions (L × W × H) | 710 × 710 × 1425 mm | 710 × 710 × 1425 mm | 1360 × 1070 × 1900 mm |
| Heating power | 15 kW | 20 kW | 30 kW |
| Power supply | AC 380 V / 50 Hz | AC 380 V / 50 Hz | AC 380 V / 50 Hz |
| Water pressure | 0.30–0.80 MPa | 0.30–0.80 MPa | 0.30–0.80 MPa |
Clean180 and Clean320 have manual doors and share the same external dimensions, while offering different chamber capacities and tray quantities. Clean520 has a larger chamber, an automatic double-door pass-through design and a higher heating power.
3. Washing, Thermal Disinfection & Drying Performance
The medical instrument washer disinfector carries out a six-stage process:
- Pre-cleaning
- Detergent washing
- Rinsing
- Final rinsing
- Disinfection with lubricant addition
- Drying
The working cycle generally takes 30–40 minutes and is adjustable. The complete washing, disinfection and drying cycle specified for Clean520 is 35–40 minutes. Actual cycle duration depends on the selected program and processing requirements.
| Performance & Consumption | Clean180 | Clean320 | Clean520 |
|---|---|---|---|
| Maximum drying temperature | 93°C | 93°C | 93°C |
| Water consumption per cycle | 15 L | 15 L | 30 L |
| Detergent consumption per cycle | 30–50 ml | 30–50 ml | 100 ml |
| Heating method | Electric heating | Electric heating | Electric heating |
The washer disinfector is equipped with rotating spray arms for water distribution, automatic detergent and lubricant dosing, automatic water heating and filtered hot-air drying.
A PLC control system with a colour touchscreen provides six preset programs. The system displays the A0 value in real time during thermal disinfection and includes automatic fault diagnosis. A thermal printer provides cycle information, including cleaning, disinfection and operator records.
Chemical disinfection and rust removal are available as optional functions.
4. Optional Accessories & Configuration
Available washer disinfector rack configurations include:
- Drying trough cleaning rack
- Four-layer instrument cleaning rack
- Bowl and dish cleaning rack
- Anesthesia and respiratory tube cleaning rack
The rack arrangement can be selected according to the instruments and containers being processed. Clean180 and Clean320 use manual doors, while Clean520 features an automatic double-door pass-through design.
When requesting a quotation, provide the instrument types, loading requirements and preferred model so that the appropriate rack and equipment configuration can be discussed.
5. Installation Requirements & Project Compatibility
Before selecting a washer disinfector, check the installation space and utility conditions at the intended site.
| Installation Item | Clean180 | Clean320 | Clean520 |
|---|---|---|---|
| External dimensions (L × W × H) | 710 × 710 × 1425 mm | 710 × 710 × 1425 mm | 1360 × 1070 × 1900 mm |
| Heating power | 15 kW | 20 kW | 30 kW |
| Power supply | AC 380 V / 50 Hz | AC 380 V / 50 Hz | AC 380 V / 50 Hz |
| Water pressure | 0.30–0.80 MPa | 0.30–0.80 MPa | 0.30–0.80 MPa |
Clean520 uses a double-door pass-through design for facilities that require separation between dirty-side loading and clean-side unloading. Confirm the available installation space, electrical supply, water pressure and site layout before placing an order.
For project planning, provide the equipment model, site conditions and relevant technical requirements when requesting technical documentation.
6. Manufacturing & Project Supply Support
Equipment supply for CSSD projects involves more than model selection. System design, technical documentation, installation, commissioning, operator training and after-sales support may also be required.
The company provides medical equipment project services covering system design, manufacturing, technical documentation, on-site installation, commissioning, training and after-sales support. Project proposals and technical documents can be developed based on the customer's user requirement specifications (URS).
For a washer disinfector project, share the planned application, instrument types, installation conditions and quantity requirements to discuss the equipment configuration and related project support.
7. Request a Washer Disinfector Quotation
To help identify a suitable washer disinfector model and configuration, include the following information in your inquiry:
- Preferred model: Clean180, Clean320 or Clean520
- Required chamber capacity or daily processing volume
- Instrument and container types
- Required cleaning racks and loading arrangement
- Installation location and available utilities
- Order quantity and project requirements
If the model has not yet been selected, you can send your instrument list, loading requirements or reference photos for an initial configuration discussion.
Contact us to request a washer disinfector quotation for your CSSD, hospital or medical equipment project.
Request a Quotation