Waste Incinerators
Our waste incinerator range covers medical waste, animal carcasses, pet remains and municipal solid waste. We offer different equipment configurations, including double-chamber combustion, optional automatic feeding and ash removal, wet scrubber systems, and mobile or containerized installations.
Medical waste incinerators are available in eight published YSL models, with maximum combustion capacities ranging from 20 to 500 kg/h.
Waste Types and Incinerator Selection
We offer different incinerator configurations according to the waste material and treatment application.
| Incinerator Type | Suitable Waste | Typical Applications |
|---|---|---|
| Medical Waste Incinerator | Infectious medical waste, sharps, pharmaceutical waste and pathological waste | Hospitals, clinics, laboratories and medical waste treatment facilities |
| Agricultural & Animal Incinerator | Animal carcasses and agricultural waste | Farms, poultry facilities, slaughterhouses and veterinary facilities |
| Pet Cremation Incinerator | Pet remains and other animal-related waste | Pet cremation facilities and animal service providers |
| Municipal Waste Incinerator | Food residues, plastics, wood, paper, cardboard and mixed general waste | Remote facilities, mining camps, hotels and general waste treatment projects |
| Mobile Incinerator | Depends on the selected incinerator configuration | Projects requiring trailer-mounted or containerized equipment |
| Continuous Feed Incinerator | Municipal waste, medical waste and industrial waste | Waste treatment projects requiring continuous feeding |
Medical Waste Incinerator Models and Specifications
Our YSL medical waste incinerators have eight models with published maximum combustion capacities from 20 to 500 kg/h.
| Model | Maximum Combustion Capacity | Primary Chamber Volume | Secondary Chamber Volume |
|---|---|---|---|
| YSL-20 | 20 kg/h | 0.2 m³ | 0.14 m³ |
| YSL-30 | 30 kg/h | 0.4 m³ | 0.2 m³ |
| YSL-50 | 50 kg/h | 0.6 m³ | 0.3 m³ |
| YSL-100 | 100 kg/h | 1.2 m³ | 0.6 m³ |
| YSL-150 | 150 kg/h | 1.5 m³ | 0.7 m³ |
| YSL-200 | 200 kg/h | 2.0 m³ | 0.9 m³ |
| YSL-300 | 300 kg/h | 2.4 m³ | 1.2 m³ |
| YSL-500 | 500 kg/h | 4.0 m³ | 1.5 m³ |
These capacities are published maximum combustion rates, not guaranteed continuous treatment outputs. Actual throughput depends on waste characteristics and operating conditions.
Combustion System and Operating Parameters
Our medical waste incinerators use a double-chamber combustion structure with primary and secondary combustion chambers.
| Parameter | Published Specification |
|---|---|
| Primary Chamber Temperature | 800–900°C |
| Secondary Chamber Temperature | ≥1100°C |
| Secondary Chamber Gas Residence Time | ≥2 seconds |
| Operational Temperature | Greater than 850°C, separately stated in the technical table |
| Combustion Structure | Double-chamber |
| Fuel Options | Diesel, LPG or natural gas |
| Temperature Monitoring | Automatic temperature monitoring |
| Control System | PLC and touchscreen control available as an option |
The furnace body has four layers: steel plate, insulation cotton, insulation brick and refractory brick. The product page specifies an outer furnace wall surface temperature below 50°C.
Flue Gas Treatment Systems
We offer a wet scrubber system with multiple treatment stages for incineration projects requiring flue gas treatment.
| Treatment Stage | Equipment or Process | Published Operating Information |
|---|---|---|
| Secondary Combustion | Secondary combustion chamber | Approximately 1100°C; residence time over 2 seconds |
| Initial Cooling and Dust Removal | Venturi spray scrubber | Flue gas cooled to approximately 200°C |
| Further Gas Treatment | Packed tower scrubber | Outlet temperature below 100°C |
| Dust Removal and Dehydration | Cyclone dust collector and dehydration | Dehydration rate above 98% |
| Exhaust Discharge | Induced draft fan and chimney | Flue gas approximately 80°C |
The system also includes water circulation and sedimentation equipment for water treatment and reuse.
A separate flue gas treatment configuration is published for continuous-feed incinerators. It includes a rapid cooling and deacidification spray tower, rotating water washing tower, activated carbon adsorption box, bag-type dust collector and induced draft fan.
These treatment configurations are specific to their respective systems and are not standard equipment for every incinerator model.
Optional Configurations and Customization
We offer different feeding, ash handling and installation configurations according to the incinerator series.
| Equipment or Configuration | Available Options |
|---|---|
| Feeding System | Manual feeding or optional automatic feeding |
| Ash Removal | Manual or optional automatic ash removal |
| Animal Incinerator Loading | Top loading; manual loading or mechanical loading using tipping equipment |
| Furnace Bed | Manual stove bed or automatic stove bed |
| Pet Cremation Furnace | Front loading or optional automatic moving hearth |
| Flue Gas Treatment | Optional wet scrubber and other treatment equipment |
| Mobile Installation | Trailer-mounted or containerized |
| Container Configuration | 20ft or 40ft High Cube |
| Continuous Feeding | Shredding, conveying and feeding system |
Automatic feeding and ash removal are optional rather than standard features across the entire product range. The available configurations depend on the selected incinerator series.
Manufacturing and Project Support
We provide engineering and project support for waste incineration equipment, including system design, equipment manufacturing, installation and commissioning.
Our project support includes:
- System design and technical documentation.
- CAD and CAXA drawing support.
- Equipment installation and commissioning guidance.
- Operator training.
- Technical assistance and after-sales support by phone, email and online communication.
For integrated waste treatment projects, we can coordinate the incinerator configuration with the corresponding feeding, ash removal and flue gas treatment equipment.
Request a Waste Incinerator Quotation
Send us your waste type, estimated hourly or daily treatment requirement, project location and any available equipment specifications or project drawings.
You can also send sample waste photographs and your required equipment quantity. We will review your application and recommend a suitable incinerator model and configuration, together with a quotation covering the proposed equipment and supply scope.