Incinerator for Medical Waste Disposal
● Suitable for infectious, sharps & pathological waste
● Dual-chamber combustion design
● Primary 800–900°C, secondary ≥1100°C
● ≥2 seconds flue gas residence time
● High efficiency, stable and reliable operation



Medical waste incinerators are designed for the safe and efficient disposal of hazardous healthcare waste, including infectious materials, sharps, pharmaceuticals, and pathological waste.
Our incinerators use advanced high-temperature combustion technology to ensure complete destruction of harmful substances while minimizing environmental impact. They are widely used in hospitals, clinics, laboratories, and waste treatment facilities.
With robust construction and reliable performance, this system provides a cost-effective and compliant solution for medical waste management.
Combustion Parameters
The incinerator is designed in accordance with WHO and EU recommendations for medical and municipal waste disposal.
- Primary combustion chamber: 800–900 °C, for drying, pyrolysis, and initial combustion of waste.
- Secondary combustion chamber: ≥1100 °C to ensure complete oxidation of flue gases.
- Residence time: Flue gases remain in the secondary chamber at the required temperature for not less than 2 seconds, with adequate turbulence and excess air to guarantee destruction of organic compounds and minimize dioxin/furan formation.
Features
High Combustion Efficiency: Dual-chamber design (primary & secondary) with optimized airflow for thorough waste destruction.
Door sealing and furnace negative pressure combustion: The design of the incinerator door and the ash cleaning door adopts a fully sealed structure of the mother-and-child type. During incineration, the inside and outside of the furnace are completely isolated, forming negative pressure combustion, eliminating secondary pollution


Robust Construction: Heavy-duty steel shell with refractory insulation for long service life and consistent thermal performance. The furnace body adopts a four-layer structure of steel plate, thermal insulation cotton, insulation bricks and refractory bricks, which makes the heat preservation inside the furnace better and the furnace wall temperature is less than 50℃.

User-Friendly Operation: Automatic temperature monitoring, PLC-based and touch screen controls(optional), and easy ash removal.
Flexible Capacities: Models from 20 kg/h to 750 kg/h, Suitable for hospitals, clinics, farms, laboratories, veterinary facilities, municipal sanitation projects, and waste treatment plants.
Reliable key parts: Our incinerators use Baltur burners from Italy. It has high combustion efficiency, low emission and environmental compliance, stable and reliable operation.

Compliance: Designed according to WHO guidelines and can be configured to meet EU emission requirements.
Customized design: We can customize according to different requirements of customers, such as mobile, automatic hearth movement, container type, top feeding and etc.
Structure


Technical specifications
|
Model |
YSL-20 |
YSL-30 |
YSL-50 |
YSL-100 |
YSL-150 |
YSL-200 |
YSL-300 |
YSL-500 |
|
Primary Combustion Chamber Volume |
0.2 m3 |
0.4 m3 |
0.6 m3 |
1.2 m3 |
1.5 m3 |
2.0 m3 |
2.4 m3 |
4.0 m3 |
|
Secondary Combustion Chamber Volume |
0.14 m3 |
0.2 m3 |
0.3 m3 |
0.6m3 |
0.7m3 |
0.9m3 |
1.2m3 |
1.5m3 |
|
Burn Rate |
Up to 20kg per hour |
Up to 30kg per hour |
Up to 50kg per hour |
Up to 100kg per hour |
Up to 150kg per hour |
Up to 200kg per hour |
Up to 300kg per hour |
Up to 500kg per hour |
|
Gas Retention in Secondary Chamber |
2 seconds |
|||||||
|
Operational Temperature |
> 850°C |
|||||||
|
Burner Power and Fuel Consumption for Combustion Chamber |
Power: 0.11kw, fuel consumption: 4~6kg/h |
Power: 0.11kw, fuel consumption: 4~6kg/h |
Power: 0.11kw, fuel consumption: 6~10kg/h |
Power: 0.11kw, fuel consumption: 6~10kg/h |
Power: 0.11kw, fuel consumption: 6~10kg/h |
Power: 0.11kw, fuel consumption: 6~10kg/h |
Power: 0.18kw, fuel consumption: 7~14kg/h |
Power: 0.18kw, fuel consumption: 7~14kg/h |
|
Burner Power and Fuel Consumption for Secondary Chamber |
Power: 0.11kw, fuel consumption: 4~6kg/h |
Power: 0.11kw, fuel consumption: 6~10kg/h |
Power: 0.18kw, fuel consumption: 7~14kg/h |
Power: 0.18kw, fuel consumption: 7~14kg/h |
Power: 0.18kw, fuel consumption: 10~20kg/h |
Power: 0.18kw, fuel consumption: 10~20kg/h |
Power: 0.25kw, fuel consumption: 10~20kg/h |
Power: 0.25kw, fuel consumption: 10~20kg/h |
|
Blower power |
0.25kw |
0.37kw |
0.55kw |
0.75kw |
0.75kw |
0.75kw |
0.75kw |
First:0.75kw Second:0.75kw |
|
Chimney |
Outer diameter: Φ280mm, height: 5m |
Outer diameter: Φ280mm, height: 6m |
Outer diameter: Φ300mm, height: 10m |
Outer diameter: Φ330mm, height: 10m |
Outer diameter: Φ360mm, height: 10m |
Outer diameter: Φ360mm, height: 10m |
Outer diameter: Φ360mm, height: 10m |
Outer diameter: Φ460mm, height: 12m |
|
Overall Size (without chimney) |
1600 × 1300 × 1750mm |
1700 × 1250 × 2500mm |
1800 × 1300 × 3000mm |
2000 × 1400 × 3300mm |
2200 × 1500 × 3500mm |
2300 × 1600 × 3500mm |
2400 × 1600 × 3800mm |
3000 × 2000 × 4800mm |
|
Fuel types |
Diesel, LPG, N-Gas |
Diesel, LPG, N-Gas |
Diesel, LPG, N-Gas |
Diesel, LPG, N-Gas |
Diesel, LPG, N-Gas |
Diesel, LPG, N-Gas |
Diesel, LPG, N-Gas |
Diesel, LPG, N-Gas |
|
Voltage |
220V / 50Hz / 60Hz; 110V / 60Hz |
220V / 50Hz / 60Hz; 110V / 60Hz |
220V / 50Hz / 60Hz; 110V / 60Hz |
220V / 50Hz / 60Hz; 110V / 60Hz |
220V / 50Hz / 60Hz; 380V / 50Hz |
220V / 50Hz / 60Hz; 380V / 50Hz |
220V / 50Hz / 60Hz; 380V / 50Hz |
220V / 50Hz / 60Hz; 380V / 50Hz |
|
Weight |
1600kg |
2500kg |
4600kg |
6500kg |
7500kg |
8000kg |
9000kg |
14000kg |
|
Door Size |
380 × 480mm |
480 × 600mm |
600 × 800mm |
700 × 900mm |
800 × 1000mm |
850 × 1050mm |
900 × 1100mm |
1000 × 1200mm |
Optional Configurations
- Automatic feeding system
- Flue gas treatment system (scrubber)
- Ash removal system
- Mobile/containerized design






Hot Tags: incinerator for medical waste disposal, China incinerator for medical waste disposal manufacturers, suppliers, Compact incinerator, Fumes Depuration Systems Wet Scrubber, hospital medical waste Incinerator, medical waste Incinerator, Pet Cremation Incinerator, sheep incinerator
Previous
No InformationYou Might Also Like
Send Inquiry