High-Pressure Steam Sterilization Technology

High-pressure steam sterilization involves introducing steam at 130-138℃ into a sealed autoclave, creating an internal pressure of 2.7~3.48 bar. Waste remains in the autoclave for 10-45 minutes to ensure thorough penetration and destruction of pathogens. Newer generations of high-pressure steam sterilization technology incorporate impregnation or shredding to further enhance steam penetration and achieve better treatment results. High-temperature steam sterilization is a simple, feasible, economical, reliable, rapid, and safe sterilization method. Medical waste treated with this method can be disposed of in sanitary landfills like ordinary household waste.

 

High-temperature steam sterilization is suitable for small-volume or big-volume medical waste disposal. It has low investment costs, simple and convenient operating procedures, and eliminates dioxin emissions and flue gas purification issues, resulting in lower overall costs. This technology is suitable for treating highly infectious medical waste, such as microbial culture media, dressings, work clothes, and syringes. It is not suitable for treating pathological waste, such as human tissue and animal carcasses, and its efficiency in treating pharmaceutical and chemical waste is also low. High-temperature steam sterilization equipment comes in various forms, including those that crush materials before sterilization and those that crush materials after sterilization. The process generates waste liquid and waste gas, and may also release trace amounts of volatile organic compounds, heavy metal ions, and other harmful substances into the environment. Therefore, the waste liquid and waste gas generated during high-temperature steam treatment must undergo sterilization and deodorization to prevent secondary pollution and meet environmental hygiene standards.

WPS1

Incineration Technology

Incineration is a high-temperature oxidation process. Inside the incinerator furnace, medical waste is burned at approximately 1000℃, essentially oxidizing the combustibles into carbon dioxide, water, and ash. This achieves thorough disinfection and sterilization, removing most pollutants. The chemically active components are fully oxidized, leaving inorganic components to form slag which is discharged. During this process, the volume of medical waste is reduced, its perishable nature is significantly altered, and the residue is easily treated. Generally, medical waste undergoes several steps during incineration, including dehydration, degassing, ignition, combustion, and extinguishing. The core of incineration technology is the rational organization of combustion and the prevention of secondary pollution.

 

A relatively complete medical waste incineration system should include a feeding system, incinerator, combustion air system, start-up and auxiliary combustion system, flue gas purification system, residue treatment system, automatic monitoring system, and emergency system.

 

Incinerators come in various combustion forms, such as fluidized bed, rotary kiln, moving bed, rotary grate, and drum grate. Common incinerators used for medical waste incineration include fixed grate incinerators, rotary kiln incinerators, and gasification pyrolysis incinerators.

 

The most commonly used and widely recognized type of incinerator with good performance is the pyrolysis incinerator, suitable for medical waste treatment of various scales. Internationally, pyrolysis incinerators are also known as controlled-gas incinerators. They consist of a primary combustion chamber and a secondary combustion chamber. In the primary combustion chamber, waste is thermally decomposed in an oxygen-deficient atmosphere, producing pyrolysis gas (a combustible gas mixture). The secondary combustion chamber primarily burns the combustible gas produced in the primary combustion chamber and any unburned waste from the primary chamber. The temperature in the secondary combustion chamber is generally controlled above 1000℃, and oil injection can be used for combustion assistance when necessary. Pyrolysis incinerators are widely used in medical waste treatment because they are easy to mechanize and automate, consume little fuel, produce relatively little exhaust gas pollution, and achieve significant volume reduction and thorough removal of pollutants.

 

WPS2

Chemical Disinfection Technology

Chemical disinfection is suitable for treating some liquid wastes in medical institutions, such as human blood, body fluids, feces, and urine, especially during infectious disease outbreaks, where it is particularly effective in treating the excrement of infectious patients. It is not suitable for treating pathological waste. When disinfecting solid medical waste, the waste to be disinfected must first be crushed.

 

Microwave Disinfection Technology

The core technology of microwave thermal effect sterilization is to utilize the thermal and non-thermal effects of microwaves to kill pathogens. Microwaves refer to electromagnetic waves with a frequency of 300 MHz.

 

Brief description of the microwave thermal effect sterilization mechanism: Biological cells are a condensed medium composed of complex compounds such as water, proteins, nucleic acids, carbohydrates, fats, and inorganic substances. Under the action of a strong microwave field, the temperature of this medium increases, its spatial structure changes or is destroyed, proteins denature, affecting their solubility, viscosity, swelling, and stability, thereby losing their biological activity.

 

A brief description of the non-thermal sterilization mechanism of microwaves: Microwaves can alter bioenergy, change the arrangement and aggregation state of biological organisms, and their movement patterns. Furthermore, the ion current induced by the microwave field affects the charge distribution near the cell membrane, leading to damage to the membrane barrier function and membrane dysfunction. This interferes with or destroys the cell's ribonucleic acid (RNA) and deoxyribonucleic acid (DNA). Under the influence of microwave field forces, hydrogen bonds can loosen, break, or recombine. This induces gene mutations or chromosomal aberrations, thereby affecting changes in biological activity and delaying or interrupting stable cell inheritance and proliferation. Simply put, microwave sterilization is the result of the combined effects of microwave thermal and non-thermal effects.

Fully automated microwave medical waste treatment systems comprehensively sterilize medical waste, rendering it harmless.

 

Microwave disinfection technology is suitable for treating most wet or moisture-rich infectious medical waste, excluding waste with toxic cellular effects, hazardous waste, or radioactive waste. It is not suitable for treating pathological waste or large metallic waste.

 

WPS3

Name

Item

High pressure steam sterilization

Incinerator

Chemical Disinfection

Microwave Disinfection

Principle

High-temperature, high-pressure steam is used to destroy pathogens, achieving sterilization.

High-temperature oxidation is used for effective treatment and waste reduction.

Chemical agents are used to disinfect medical waste.

Microwaves utilize both thermal and non-thermal effects to kill pathogens and can also reduce waste volume to some extent.

Temperature

130-138℃

500-1300℃

-

≥95℃

Suitable treatment Products

Infectious medical waste, sharps medical waste, and some pathological waste

Infectious medical waste, sharps medical waste and some pathological waste, radioactive medical waste, and chemical medical waste.

Infectious medical waste

Infectious medical waste, chemical waste

Treatment capacity

Small

Big

Small

Big

Posttreatment

Exhaust gas is purified before being discharged; wastewater is treated biochemically and disinfected before being discharged; sterilized waste is disposed of together with domestic garbage.

Slag is collected and landfilled; fly ash needs to be collected and further treated; flue gas needs to be dust-removed, acid-removed, cooled before being discharged, and waste heat can be recovered.

--

After exhaust gas purification, the sterilized waste can be disposed of together with household garbage.

Environmental risks

Generally

Generally

large

Generally

Equipment investment

Low

High

Low

Low


 