Hydrogen Peroxide Sterilization Evaluation Resistometer
video

Hydrogen Peroxide Sterilization Evaluation Resistometer

A hydrogen peroxide sterilization evaluation resistometer is a specialized laboratory device, also known as a Biological Indicator Evaluator Resistometer (BIER),
Used to test the resistance of biological indicators (BIs) to vaporized hydrogen peroxide (H2O2) sterilization conditions.
It creates a controlled and reproducible environment that mimics the sterilization process, allowing for accurate and consistent testing of how effectively microbial populations are destroyed by the sterilant.
Send Inquiry
Product Introduction
product-1276-1276
Hydrogen Peroxide Sterilization Evaluation Resistometer

The Hydrogen Peroxide Sterilization Evaluation Resistometer is specially designed to test biological indicators, chemical indicators, and biochemical PCD performance for hydrogen peroxide gas sterilization.

It is composed of:

● Gasified hydrogen peroxide generation chamber

● Resistance detection (testing) chamber

● Vacuum system

● Hydrogen peroxide purification and gasification injection system

● Electrical control, display, and recording system

● High-precision sensors and connecting pipelines

Both the vaporization and detection chambers, as well as the automatic lift doors, are made from high-strength aluminum alloy for durability and precision.

 

Test Programs

 

1. Standard Procedure

(Used for biological and chemical indicator testing)
1.Preheat both chambers to the required temperature (e.g. 50 °C)
2.Vacuum to 50 Pa
3.Inject hydrogen peroxide into the generating chamber for vaporization
4.Vacuum the detection chamber to 15 Pa
5.Inject the vaporized H₂O₂ gas to reach the target concentration
6.Maintain sterilization for the set time
7.Vacuum and re-aerate the detection chamber
8.Open the automatic chamber door for sample retrieval
9.Plasma release and air intake reset the generating chamber to zero

2. Enhanced Procedure

(Used for biochemical PCD testing)
1.Preheat the generating chamber to the set temperature (e.g. 50 °C)
2.Vacuum to 50 Pa
3.Inject H₂O₂ into the purification and vaporization system
4.Deliver prepared vapor to the generating chamber
5.Maintain sterilization for the set duration
6.Vacuum, plasma release, and air re-introduction
7.Return the chamber to initial conditions

 

Technical parameters

 

Parameter

Specification

Vacuum pressure (before H₂O₂ injection)

80 Pa ± 5 Pa

Working temperature

50 °C ± 0.5 °C

H₂O₂ concentration (during operation)

2.7 ± 0.3 mg/L (real-time display)

Chambers

Diffusion vaporization chamber – 135 L; Detection chamber – 1.5 L

Door type

Electric lift doors (both chambers)

H₂O₂ injection devices

hydrogen peroxide injection devices and vaporization devices

Multiple Pressure transmitters

Display accuracy 0.1 Pa; Control accuracy ± 5 Pa

Control valve

Installed between the large chamber and the small chamber to accurately control the sterilization time of the detection chamber.

Temperature control

Display unit 0.1 °C; Control accuracy ± 0.5 °C

Injection/removal time of H₂O₂

≤ 5 s for both

Main control components

Siemens (Germany) – PLC, touchscreen, temp/pressure modules

Solenoid valves

SMC (Japan)

Recording system

Built-in micro-printer for real-time data output

Power

6 kW

Overall Size (L×W×H)

900 × 1100 × 1700 mm

Weight

300 kg

Hot Tags: hydrogen peroxide sterilization evaluation resistometer, China hydrogen peroxide sterilization evaluation resistometer manufacturers, suppliers, biological indicator evaluation resistometer, Chemical Indicator Evaluation Resistometer, Ethylene Oxide Gas Sterilization Evaluation Resistometer, Ethylene Oxide Indicator Evaluator Resistometer, Hydrogen Peroxide Sterilization Evaluation Resistometer, Steam Sterilization Evaluation Resistometer